ContactFronius CanadaAccueil

 

Guide de grosseur de cable

 

 

 

GROSSEUR DE CABLE ( DE CUIVRE ) À UTILISER SELON LA LONGUEUR APPROPRIÉE. COMPTABILISER LA LONGUEUR DU POSITIF ET DU NÉGATIF.
(EXEMPLE : 100 PIEDS DE CABLES DE MISE À LA TERRE + 100 PIEDS DE PORTE ÉLECTRODE, POUR UNE UTILISATION À 200A, IL FAUT UN FIL 1/0)
  100pi (30M)
OU MOINS
150pi
(45M)
200pi
(60M)
250pi
(70M)
300pi
(90M)
350pi
(105M)
400pi
(120M)
AMPÉRAGE
DE SOUDAGE
10-60%
FACTEUR DE MARCHE
AWG (MM²)
60-100%
FACTEUR DE MARCHE
AWG (MM²)
10-100%
FACTEUR DE MARCHE
AWG (MM²)
100 4 (20) 4 (20) 4 (20) 3 (30) 2 (35) 1 (50) 1/0 (60) 1/0 (60)
150 3 (30) 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 3/0 (95)
200 3 (30) 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 4/0 (120)
250 2 (35) 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2X 2/0 (2x70) 2 CH. 2/0 (2x70)
300 1 (50) 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2 CH. 3/0 (2x95)
350 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2x 3/0 (2x95) 2 CH. 4/0 (2x120)
400 1/0 (60) 2/0 (70) 3/0 (95) 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2x CH. 4/0 (2x120) 2 CH. 4/0 (2x120)
500 2/0 (70) 3/0 (95) 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2x 4/0 (2x120) 3x 3/0 (3x95) 3x 3/0 (3x95)
600 3/0 (95) 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2x 4/0 (2x120) 3x 3/0 (3x95) 3x 4/0 (3x120) 3 CH. 4/0 (3x120)
700 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2x 4/0 (2x120) 3x 3/0 (3x95) 3x 4/0 (3x120) 3x 4/0 (3x120) 4 CH. 4/0 (4x120)
800 4/0 (120) 2x 2/0 (2x70) 2x 3/0 (2x95) 2x 4/0 (2x120) 3x 4/0 (3x120) 3x 4/0 (3x120) 4x 4/0 (4x120) 4x 4/0 (4x120)

* CETTE CHARTE EST UN GUIDE GÉNÉRAL ET NE PEUT CONVENIR À TOUTES LES APPLICATIONS. SI LES CABLES SURCHAUFFENT, UTILISEZ LA GROSSEUR SUIVANTE.

 

*EN PULSÉE SOUS 300A; UTILISEZ DU 2/0 ET DE 300A-450A, UTILISEZ DU 4/0.